CALL US : 305-252-1772
Every exterior door and window in a Florida hurricane zone must resist a wind pressure specific to its site, not a generic catalog value. We provide the structural analysis needed to correctly specify, calculate and document opening requirements in line with the Florida Building Code 8th Edition (2023) and ASCE 7-22.
A product with the wrong design pressure (DP) rating, or without the impact protection required for the applicable zone, can result in permitting problems, insurance issues or opening failure during a storm.
Hurricane-zone openings have site-specific requirements. Our service helps determine the design pressure for each opening and verifies whether the planned door or window has the certification and DP rating needed for the project.
Determination of the design wind pressure for each opening based on location, height, exposure category and building risk category, following the Components and Cladding (C&C) method of ASCE 7-22.
Review confirming that a product's certified DP rating, including Miami-Dade NOA, Florida Product Approval or Broward BC documentation, meets or exceeds the calculated demand for the site.
Specification of the frame-to-substrate fastening system for concrete, block or wood based on the calculated design pressure.
Verification of whether the project falls within the HVHZ (Miami-Dade/Broward), a Wind-Borne Debris Region (WBDR), or neither, and what level of opening protection applies.
Technical documentation with the calculated design pressures, prepared to accompany your permit application to the relevant building department.
Replacing doors or windows on your home? We help confirm whether your zone requires impact certification and verify that the product you chose has the correct DP rating before the inspector arrives.
Specialized HVHZ technical support to complement your design team on projects where the exterior envelope requires close coordination between architecture and wind loads.
Design pressure reports ready to include in permit packages, with support for multi-unit or development projects.
After Hurricane Andrew (1992), Florida adopted some of the strictest wind codes in the country. A design pressure that is calculated incorrectly, or pulled from a generic table, can significantly underestimate the real load at corners and edge zones, where suction forces are highest.
In HVHZ zones like Miami-Dade and Broward, design pressures frequently exceed 50-80 psf, and every opening must be justified individually.
We serve projects throughout South Florida, including Miami, Coral Gables, Pinecrest, Palmetto Bay, Doral, Hialeah, Miami Lakes, South Miami, Miami Beach, Miramar, Hollywood, Pembroke Pines, Fort Lauderdale and Weston.
Send us the address and scope of work, and we'll tell you exactly what applies to your case.